The Feasa LED Spectrometer delivers absolute, traceable measurements of LED colour and intensity in a compact, robust design suited to both laboratory and production environments. Operating across 380–780nm with on-board firmware for automatic colour calculation, it generates the golden reference data your LED Analyser production setups need — and transfers values seamlessly across the entire Feasa analyser range.

Feasa LED Spectrometer

Overview

Absolute measurement units are essential for accurate LED testing in industries where consistent, traceable results are a quality requirement. Traditional spectrometers often fall short — laboratory-only designs, complex operation, and calibration using a single bulb source that doesn't represent real LED behaviour. The Feasa LED Spectrometer was designed to address exactly these limitations.

The Feasa LED Spectrometer S2 delivers traceable measurements in a practical, compact and robust format ideal for desktop and production use. Crucially, Feasa's manufacturing calibration process uses a range of LEDs — not just a single bulb — making it far better suited to real-world LED measurement than traditional instruments. With a spectral range of 380–780nm, 0.1nm wavelength resolution and integration times from 10µs to 4 seconds, it handles everything from rapid production screening to detailed laboratory characterisation.

The Spectrometer is specifically designed for testing LEDs on populated PCBs where access is limited. On-board firmware calculates colour automatically in multiple colour spaces, using the same simple command structure as the Feasa LED Analyser. Values transfer directly to Feasa LED Analysers to validate production calibration. Three adapter families extend its capability — Miniature Integrating Spheres (Luminous Flux in Lumens), Luminous Intensity Heads (Candela) and Luminance Heads (cd/m², for automotive displays) — all using FP02 armoured patch cords. Multiple Spectrometers can be Daisy Chained, with PWM capture, sequence capture (up to 450 measurements) and external trigger input supported.

The reference standard. Trusted globally.

Absolute, traceable measurements

Measures in real physical units — Lumens, Candela, cd/m², Watts — calibrated relative to a traceable standard. ±0.005 CIE xy chromaticity accuracy. Calibrated using a range of LEDs, not just a bulb, ensuring the calibration reflects real-world LED behaviour.

380–780nm full visible spectrum

Full spectral range from UV-edge to near-IR with 0.1nm minimum wavelength step. Integration time 10µs to 4 seconds with automatic exposure control and range selection built-in. Ideal for RGB LEDs, colour mixing and white LED characterisation.

Compatible with all Feasa LED Analysers

Transfer measurements directly to any Feasa LED Analyser to create golden reference boards and calibrate production setups. Uses the same command structure as the Feasa LED Analyser, minimising integration effort. Daisy Chain for multiple units from a single port.

40+ years expertise

Engineering LED test solutions since the early 2000s, headquartered in Limerick, Ireland.

Millions of LEDs daily

Tested every day worldwide via Feasa systems across automotive, medical and electronics production lines.

ISO 9001 certified

Full in-house design, development and manufacturing. Deployed in 30+ countries worldwide.

Applications

Where our LED Spectrometer is commonly used.

  • Golden Reference Board Generation

    Production Calibration

    Golden Reference Board Generation

  • RGB LED Calibration

    RGB LEDs

    RGB LED Calibration

  • LED Characterisation and Binning

    Laboratory

    LED Characterisation and Binning

  • Production Line Verification

    Production

    Production Line Verification

Technical Specifications

ParamètreValeurRemarques
Spectral range380–780 nmFull visible spectrum
Min wavelength step0.1 nmHigh resolution
Integration time10 µs to 4 sAutomatic exposure control
CIE xy chromaticity accuracy±0.005After calibration with integrating sphere
Power accuracy (Watts)10%After calibration
Luminous Flux accuracy10%After calibration
Peak wavelength accuracy±1 nm
Wavelength repeatability±0.5 nmExcellent consistency
Chromaticity xy repeatability±0.0005Precision measurement
Intensity repeatability< 1%
InterfaceUSB 2.0, RS232, Daisy Chain, Ext. TriggerFlexible connectivity
Supply current (USB)180 mAUSB bus powered
Dimensions125 × 54 × 32 mmIncluding brackets
Fiber diameter5.1 mm incl. claddingArmoured fibre
Operating temperature0–40°CNarrower than most Feasa analysers
Special functionsPWM, Sequence Capture (450), Ext. Trigger
Integrating Sphere adaptersSP13, SP23, SP16, SP26Luminous Flux (Lumens)
Luminous Intensity adaptersCD02, CD04, CD08Candela — CIE Condition B
Luminance adaptersLU01, LU02, LU04, LU07cd/m² — automotive displays
Adapter patch cordFP02 (600mm, FC-PC to SMA)Used by all adapters
ComplianceCE, RoHSEU standards
Model numberFeasa S2

Feasa Spectrometer Software Suite

Feasa Spectrometer Software Suite

Included — Windows 11 / 10 / 8 / 7 / Vista / XP

  • Graphical Display ProgramReal-time full spectrum display and CIE xy chromaticity diagram
  • Datalogging and compareLog measurements over time, compare against stored references
  • Terminal & Scripting ProgramCommand-line control with CSV export
  • Feasa Spectrometer SoftwareCalibration workflow, golden board generation, Analyser value transfer
  • Test Software and User CalAlso included with every unit
  • DLL/SDKProgramming examples in LabVIEW, C++, Python
Download SDK →

Downloads and Resources

Spectrometer Datasheet

Spectrometer Datasheet

PDF

Adapter Datasheets

Adapter Datasheets

PDF

2025 Catalogue

2025 Catalogue

PDF

Have a question about this product?

Our engineers are happy to help — get in touch and we'll come back to you.